EasyManua.ls Logo

TKS K2 - Page 58

TKS K2
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TKS Operator's manual
58
15 FK2
Communication
fault
Communication error
between PLC and
the inverter for the
conveyor belt – FK2
Communication with
the inverter has been
lost
Reset error message and try
again
If the error recurs – contact
service personnel
16 Communication
fault
The Magazine is empty The magazine is
defective or the
settings on the control
are incorrect
The settings for the
magazine are incorrect
The machine will not
disable.
Fill with forage
Check the settings for the
R2 Magazine
Check that the machine goes
to the fi lling position during
lling
17 Magazine fault! The machine has
slipped out of the load-
ing position in front of
the magazine during
loading
(more than 45 cm)
The round bale has not
been fully loaded
The settings in the
control for the
R2 Magazine are
incorrect
Place the round bales
properly on the
magazine at right angles to it
Leave a bit of space between
the bales
Check the settings and
function of the R2 Magazine
If a round bale is hanging
between the magazine and
the machine, the
“Emergency Filling” function
can be used to load the bale.
See the Forage menu
18 Feeding weight
error
The weight of the
machine’s
contents is not reduced
when the machine dis-
penses feed
The machine is empty,
but the photocell does
not detect this
The conveyor belt
does not run
Clean photocell lenses
Check adjustment on the
photocell
Check the settings for the
conveyor belt
19 Weighing
system –
communication
error
Communication to the
weighing system has
been lost
Incorrect settings in the
weighing cell amplifi er
The weighing system
on the machine is disa-
bled, but it is enabled
in the system settings
Incorrect settings in the
weighing cell amplifi er
The weighing system
on the machine is
disabled, but it is
enabled in the system
settings.
Check settings in the
weighing cell amplifi er
Disable the weighing system
in the System menu if the
machine is not tted with one

Table of Contents