22 Grain feed 1 (2)
lling time
exceeded
Time to fi ll
Grain feed 1 (2) exceeds
the pre-set “Max lling
time” in the settings
Grain feed fi lling does
not work
Contact rail for signal
transmission is not
working or is incor-
rectly fi tted
Positioning of the ma-
chine in the lling bay
is not correct
It takes longer to fi ll
up the grain feed tank
than the time
provided by the
“Max fi lling time”
Upper tank sensor or
the sensor cable is
defective
Check that the
grain feed silo is working
Check that the machine
emits a +24V DC signal on
the grain feed lling
connector.
Check that the contact rail for
signal transmission is
receiving a signal.
Check that the machine
stops at the right place to fi ll
grain feed.
Adjust “Max fi lling time” to
make it slightly longer than
the time needed to
completely refi ll an empty
grain feed tank.
Check that the upper
tank sensor emits a signal
23 Grain feed 1 (2)
motor fault
Grain feed
motor 1 (2) should
rotate but does not
receive feedback from
the counting sensor
Concentrate auger has
clogged
Use concentrate feed
as stick
Engine is defective
Check if the grain screw is
clogged
Use a grain that does not
stick together
Replace motor
24 Grain feed 1 (2)
tanksensor fault
Grain feed 1 (2) upper
sensors gives signal,
while lower
sensor doesn`t.
The sensitivity of the
sensors is not adjusted
correctly
The sensors or the
cables are defective
The grain can be hard,
sticky or very light, and
this causes cavities
to form in front of the
sensor.
The sensor can thus
not "see" the grain
Adjust the sensitivity of the
sensor. The sensor should
be adjusted into the tank so
that the tip is level with the
inside of the nipple where the
sensor is attached
Change sensor
Move sensor location
(Drill a new hole)
25 Empty machine -
Missed feeding
If the machine is
running in multifi ll
mode, and it is empty
when forage starts, then
this alarm is given.
Check whether refi ll is
entered in sequence,
or if the refi ll quantity is
less than the amount
of feeding.
Enter the command again.