Page 5-22 Document Ref 942583-001 Rev 8
Installation Quantium 510 Installation Manual
5.4.8 LEAK PLATE SEALING
To fulfill to ECN13617-1, it is required to apply sealant between leak-plate and
island (or alternatively cradle) or between integrated drip-tray and island (or
alternatively cradle) as per instruction hereafter.
Apply suitable fuel resistant sealant on the surface of the leak-plate/integrated
drip-tray, apply suitable fuel resistant sealant around fixing holes on the island as
per below sketch - sealant represented by blue line.