Alternatively,youcanuseananti-foamingagent
inthetank.
5.Usetherateswitchtoadjustandsetatarget.
6.Whennishedspraying,setthemaster-section
switchtotheOFFpositiontoturnoffallsections,
thensetthepumpswitchtotheOFFposition.
SprayingTips
•Donotoverlapareasthatyouhavepreviously
sprayed.
•Watchforpluggednozzles.Replaceallwornor
damagednozzles.
•Usethemaster-sectionswitchtostopthespray
owbeforestoppingthesprayer.Oncestopped,
placetherangeselectorintheNEUTRALposition
andusetheneutralenginespeedlocktoholdthe
enginespeeduptokeeptheagitationrunning.
•Youwillobtainbetterresultsifthesprayeris
movingwhenyouturnthesectionson.
•Watchforchangesintheapplicationratethatmay
indicatethatyourspeedhaschangedbeyondthe
rangeofthenozzlesorthereisaproblemwiththe
spraysystem.
CalibratingtheSprayer
Flow
Beforeusingthesprayerforthersttime,ifyou
changethenozzles,orasneeded,calibratethe
sprayerow.
Operatorsuppliedequipment:Stopwatchcapable
ofmeasuring±1/10secondandacontainergraduated
in50ml(1oz)increments.
PreparingtoCalibratetheSprayer
Flow
1.Fillthespraytankwithcleanwater.
Note:Ensurethatthereisenoughwaterinthe
tanktocompletethecalibration.
2.Settheparkingbrakeandturntheengineon.
3.SetthepumpswitchtotheONposition,andturn
ontheagitation.
4.Pressdownontheacceleratorpedaluntilyou
reachthemaximumenginespeed,andtoggle
thethrottlelockswitchtotheONposition.
PerformingaCatchTest
1.Setall3sectionswitchesandthemaster-section
switchtotheONposition.
2.Turnthesupervisor(rate-lockout)switchtothe
UNLOCKposition.
3.Preparetoperformacatchtestusingthe
graduatedcontainer.
4.Startat2.75bar(40psi)andusethe
application-rateswitchtoadjustthespray
pressuresoacatchtestyieldstheamounts
listedinthetablebelow.
Note:Repeatthetest3timesandusethe
average.
NozzleColor
Milliliters
collectedin15
seconds
Ouncescollected
in15seconds
Yellow1896.4
Red37812.8
Brown47316.0
Gray
56719.2
White
757
25.6
Blue94632.0
Green
1,41948.0
5.Oncethecatchtesthasyieldedtheamounts
listedinthetableabove,setthesupervisorrate
lockoutswitchtotheLOCKposition.
6.Turnoffthemaster-sectionswitch.
PerformingtheSprayerFlow
Calibration
1.OntheInfoCenter,navigatetotheCalibration
menuandselectFLOWCALasfollows:
Note:SelectingtheHomeScreeniconatany
timecancelscalibrations.
A.Pressthecenterselectionbuttononthe
InfoCentertwicetoaccessthemenus.
B.Enterthecalibrationmenubypressingthe
rightselectionbuttonontheInfoCenter.
C.SelectFLOWCALbyhighlightingFLOWCAL
andpresstherightselectionbuttononthe
InfoCenter.
D.Inthenextscreen,entertheknownquantity
ofwaterthatwillbesprayedoutofthe
sectionsforthecalibrationprocedure;refer
tothechartbelow.
E.Presstherightselectionbuttononthe
InfoCenter.
30