EasyManuals Logo

Toro Multi Pro 1750 Operator's Manual

Toro Multi Pro 1750
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Alternatively,youcanuseananti-foamingagent
inthetank.
5.Usetherateswitchtoadjustandsetatarget.
6.Whennishedspraying,setthemaster-section
switchtotheOFFpositiontoturnoffallsections,
thensetthepumpswitchtotheOFFposition.
SprayingTips
Donotoverlapareasthatyouhavepreviously
sprayed.
Watchforpluggednozzles.Replaceallwornor
damagednozzles.
Usethemaster-sectionswitchtostopthespray
owbeforestoppingthesprayer.Oncestopped,
placetherangeselectorintheNEUTRALposition
andusetheneutralenginespeedlocktoholdthe
enginespeeduptokeeptheagitationrunning.
Youwillobtainbetterresultsifthesprayeris
movingwhenyouturnthesectionson.
Watchforchangesintheapplicationratethatmay
indicatethatyourspeedhaschangedbeyondthe
rangeofthenozzlesorthereisaproblemwiththe
spraysystem.
CalibratingtheSprayer
Flow
Beforeusingthesprayerforthersttime,ifyou
changethenozzles,orasneeded,calibratethe
sprayerow.
Operatorsuppliedequipment:Stopwatchcapable
ofmeasuring±1/10secondandacontainergraduated
in50ml(1oz)increments.
PreparingtoCalibratetheSprayer
Flow
1.Fillthespraytankwithcleanwater.
Note:Ensurethatthereisenoughwaterinthe
tanktocompletethecalibration.
2.Settheparkingbrakeandturntheengineon.
3.SetthepumpswitchtotheONposition,andturn
ontheagitation.
4.Pressdownontheacceleratorpedaluntilyou
reachthemaximumenginespeed,andtoggle
thethrottlelockswitchtotheONposition.
PerformingaCatchTest
1.Setall3sectionswitchesandthemaster-section
switchtotheONposition.
2.Turnthesupervisor(rate-lockout)switchtothe
UNLOCKposition.
3.Preparetoperformacatchtestusingthe
graduatedcontainer.
4.Startat2.75bar(40psi)andusethe
application-rateswitchtoadjustthespray
pressuresoacatchtestyieldstheamounts
listedinthetablebelow.
Note:Repeatthetest3timesandusethe
average.
NozzleColor
Milliliters
collectedin15
seconds
Ouncescollected
in15seconds
Yellow1896.4
Red37812.8
Brown47316.0
Gray
56719.2
White
757
25.6
Blue94632.0
Green
1,41948.0
5.Oncethecatchtesthasyieldedtheamounts
listedinthetableabove,setthesupervisorrate
lockoutswitchtotheLOCKposition.
6.Turnoffthemaster-sectionswitch.
PerformingtheSprayerFlow
Calibration
1.OntheInfoCenter,navigatetotheCalibration
menuandselectFLOWCALasfollows:
Note:SelectingtheHomeScreeniconatany
timecancelscalibrations.
A.Pressthecenterselectionbuttononthe
InfoCentertwicetoaccessthemenus.
B.Enterthecalibrationmenubypressingthe
rightselectionbuttonontheInfoCenter.
C.SelectFLOWCALbyhighlightingFLOWCAL
andpresstherightselectionbuttononthe
InfoCenter.
D.Inthenextscreen,entertheknownquantity
ofwaterthatwillbesprayedoutofthe
sectionsforthecalibrationprocedure;refer
tothechartbelow.
E.Presstherightselectionbuttononthe
InfoCenter.
30

Table of Contents

Other manuals for Toro Multi Pro 1750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Multi Pro 1750 and is the answer not in the manual?

Toro Multi Pro 1750 Specifications

General IconGeneral
BrandToro
ModelMulti Pro 1750
CategoryPaint Sprayer
LanguageEnglish

Related product manuals