Toro Multi Pro 1750 - Calibrating the Sprayer Speed; Calibrating the Section-Bypass Valves

Toro Multi Pro 1750
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.Usingtheplus(+)andminus(-)symbols,enter
theowvolumeaccordingtothetablethat
follows:
NozzleColor
Liters
USGallons
Yellow4211
Red8322
Brown10628
Gray
12533
White16744
Blue208
55
Green
31483
3.Turnonthemaster-sectionswitchfor5minutes.
Note:Asthemachinesprays,theInfoCenter
displaysthequantityofuidthatitiscounting.
4.Afterthe5minutedurationofsprayingclickthe
checkmarkbypressingthecenterbuttononthe
InfoCenter.
Note:Itisacceptableifthegallonsdisplayed
duringthecalibrationprocessdonotmatch
theknownquantityofwaterenteredintothe
InfoCenter.
5.After5minutes,turnoffthemaster-section
switchandselectthecheckmarkonthe
InfoCenter.
Note:Calibrationisnowcomplete.
CalibratingtheSprayer
Speed
Beforeusingthesprayerforthersttime,ifyou
changethenozzles,orasneeded,calibratethe
sprayerspeed.
1.Fillthetankwithfreshwater.
2.Onanopen,atarea,markoffadistance
between45to152m(150to500ft).
Note:Tororecommendsmarkingoff152m
(500ft)formoreaccurateresults.
3.Starttheengineanddrivetothestartofthe
marked-offdistance.
Note:Alignthecenterofthefronttireswiththe
startinglineforthemostaccuratemeasurement.
4.OntheInfoCenter,navigatetotheCalibration
menuandselectSPEEDCAL.
Note:SelectingtheHomeScreeniconatany
timecancelscalibrations.
5.SelecttheNextarrow(→)ontheInfoCenter.
6.Usingtheplus(+)andminus(-)symbols,enter
themarked-offdistanceintotheInfoCenter.
7.Shiftthemachineintorstgearanddrivethe
markeddistanceinastraightlineatfullthrottle.
8.Stopthemachineatthemarked-offdistance
andselectthecheckmarkontheInfoCenter.
Note:Slowdownandrolltoastoptoalignthe
centerofthefronttireswiththenishline,for
themostaccuratemeasurement.
Note:Calibrationisnowcomplete.
Calibratingthe
Section-BypassValves
Beforeusingthesprayerforthersttime,ifyou
changethenozzles,orasneeded,calibratethe
sprayersectionbypass
Important:Selectanopenatareatoperform
thisprocedure.
PreparingtoCalibratethe
Section-BypassValves
1.Fillthespraytankhalfwaywithcleanwater.
2.Lowerthesprayersections.
3.MovetherangeselectortotheNEUTRALposition
andsettheparkingbrake.
4.Setthe3sectionswitchestotheONposition,
butleavethemaster-sectionswitchoff.
5.SetthepumpswitchtotheONposition,andturn
ontheagitation.
6.Pressdownontheacceleratorpedaluntilyou
reachthemaximumenginespeed,andtoggle
thethrottlelockswitchtotheONposition.
7.OntheInfoCenter,navigatetotheCalibration
menuandselectTESTSPEED.
Note:SelectingtheHomeScreeniconatany
timecancelsthecalibration.
8.Usingtheplus(+)andminus(-)symbols,enter
atestspeedof5.6km/h(3.5mph),thenselect
theHomeicon.
9.Turnthesupervisor(rate-lockout)switchtothe
UNLOCKposition,andturnthemaster-section
switchtotheONposition.
31