TroubleshootingtheSpraySystem
Problem
PossibleCauseCorrectiveAction
1.Theelectricalconnectiononthe
sectionvalveisdirtyordisconnected.
1.Turnthevalveoffmanually.Disconnect
theelectricalconnectoronthevalve
andcleanallleads,thenconnectit.
2.Thereisablownfuse.2.Checkthefusesandreplacethemas
necessary.
3.Thereisapinchedhose.3.Repairorreplacethehose.
4.Asectionbypassisimproperly
adjusted.
4.Adjustthesectionbypass.
5.Therearedamagedsectionvalve.
5.ContactyourAuthorizedService
Dealer.
Asectiondoesnotspray.
6.Theelectricalsystemisdamaged.
6.ContactyourAuthorizedService
Dealer.
Asectiondoesnotturnoff.
1.Thesectionvalveisdamaged.
1.Disassemblethesectionvalve;refer
tothesectionCleaningtheSprayer
Valves.Inspectallofthepartsand
replaceanythataredamaged.
Asectionvalveisleaking.1.Asealiswornordamaged.1.Disassemblethevalveandreplace
thesealsusingtheValveRepair
Kit;contactyourAuthorizedService
Dealer.
1.Thesectionbypassisimproperly
adjusted.
1.Adjustthesectionbypass.
2.Thereisanobstructioninthesection
valvebody.
2.Removetheinletandoutlet
connectionstothesectionvalve
andremoveanyobstructions.
Apressuredropoccurswhenyouturnon
asection.
3.Anozzlelterisdamagedorclogged.
3.Removeandinspectallnozzles.
71