Bleeding Air from the Injectors (continued)
G415052
Fuel injectors
4. Move the throttle to the FAST position.
5. Turn the key to the S
TART position and watch the fuel flow around the connector. Turn the
key to the O
FF position when there is a continuous flow.
IMPORTANT
To prevent overheating of the starter motor, do not engage the starter for longer than
15 seconds. After 10 seconds of continuous cranking, wait 60 seconds before
engaging the starter motor again.
6. Tighten the tube nut securely.
7. Clean any fuel from the engine.
8. Repeat steps 3 through 7 for the remaining fuel-injector nozzles.
9. Start the engine, check for leaks, and shut off the engine.
Note: Repair all fuel leaks.
10. Close and latch the hood.
Electrical System Maintenance
Servicing the Battery
DANGER
Battery electrolyte contains sulfuric acid, which is lethal if consumed and causes
severe burns.
• Do not drink electrolyte and avoid contact with skin, eyes, or clothing.
• Wear safety glasses and rubber gloves.
• Fill the battery where clean water is always available for flushing the skin.
Maintenance: Electrical System Maintenance Page 6–20 3466-297 A