TestingtheliftCircuit–ReliefValve(SVRV)Pressure(5610-D)
g216147
Figure136
Performtheliftreliefvalve(SVRV)pressuretesttoensurethattheliftcircuit
reliefpressureiscorrect.
TestProcedure
1.Ensurethatthehydraulicuidisatnormaloperatingtemperatureby
operatingthemachineforatleast10minutes.
2.Parkthemachineonalevelsurfacewiththereelengageswitchoff,lowerthe
cuttingunits,shutofftheengine,mowspeedlimiterisintheMOWposition,
andsettheparkingbrake.
3.ReadallWarning,Cautions,andprecautionslistedatthebeginningofthis
section.
HydraulicSystem:TestingtheHydraulicSystem