SettingsScreen(continued)
BladeCount:Thebladecountsettingshouldmatchthenumberofbladesonthe
cuttingunitreelsinstalledonthemachine.Thebladecountsettingisusedbythe
TECtomanagethecuttingunitreelspeed.Usetheleft/rightbutton(asindicated
bytheatthebottomofthescreen)toselect8or11.Thefaultindicatorwill
illuminateandanoperatoradvisory#176(ReelSpeedChanged)willappearon
theInfoCenterdisplaytoconrmthatthechangehasbeenrecorded.
MowSpeed:Themowspeedsettingshouldmatchthecurrentmowspeedlimiter
settingonthemachine.ThemowspeedsettingisusedbytheTECtomanage
thecuttingunitreelspeed.Presstheleft/rightbutton(asindicatedbytheat
thebottomofthescreen)thenusethedownbuttontodecreaseortheleft/right
buttontoincreasethemowspeedin0.8kph(0.5mph)increments.Thefault
indicatorwillilluminateandanoperatoradvisory#176(ReelSpeedChanged)will
appearontheInfoCenterdisplaytoconrmthatthechangehasbeenrecorded.
HeightofCut(HOC):TheHOC(heightofcut)settingshouldmatchthecurrent
cuttingunitHOC.TheHOCsettingisusedbytheTECtomanagethecutting
unitreelspeed.Presstheleft/rightbutton(asindicatedbythe
atthebottom
ofthescreen)thenusethedownbuttontodecreaseortheleft/rightbuttonto
increasetheHOCin1.59mm(0.063inch)increments.Thefaultindicatorwill
illuminateandanoperatoradvisory#176(ReelSpeedChanged)willappearon
theInfoCenterdisplaytoconrmthatthechangehasbeenrecorded.
FReelRPM:Initially,thefrontreelspeedissetbytheTECbasedonthevalues
enteredforbladecount,mowspeed,andHOC.ThefrontreelRPMcanalso
bemanuallyadjusted.Usetheleft/rightbutton(asindicatedbythe
atthe
bottomofthescreen)tomanuallyadjustthereelRPM.Thefaultindicatorwill
illuminateandanoperatoradvisory#176(ReelSpeedChanged)willappearon
theInfoCenterdisplaytoconrmthatthechangehasbeenrecorded.TheTEC
calculatedRPMisreferencedbywhenreelRPMismanuallyset.
AmanualRPMadjustmentwillremainactiveuntilthebladecount,mowspeed,
orHOCsettingischanged.Whenoneofthecuttingunitsettingsischanged,the
reelRPMwillreturntotheTECcalculatedspeed.
RReelRPM:Initially,therearreelspeedissetbytheTECbasedonthevalues
enteredforbladecount,mowspeed,andHOC.TherearreelRPMcanalso
bemanuallyadjusted.Usetheleft/rightbutton(asindicatedbythe
atthe
bottomofthescreen)tomanuallyadjustthereelRPM.Thefaultindicatorwill
illuminateandanoperatoradvisory#176(ReelSpeedChanged)willappearon
theInfoCenterdisplaytoconrmthatthechangehasbeenrecorded.TheTEC
calculatedRPMisreferencedbywhenreelRPMismanuallyset.
AmanualRPMadjustmentwillremainactiveuntilthebladecount,mowspeed,
orHOCsettingischanged.Whenoneofthecuttingunitsettingsischanged,the
reelRPMwillreturntotheTECcalculatedspeed.
ElectricalSystem:InfoCenterDisplay
Page7–24
Reelmaster
®
5410/5510/5610Series
15216SLRevC