EasyManua.ls Logo

Toro Z MASTER 2000 Series - Page 105

Toro Z MASTER 2000 Series
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LH & RH Control Assembly Installation (continued)
3. Using a 1/2 inch socket, install the (1/2 inch) nut to secure the LH & RH
motion control linkages to the transaxle assembly . T orque to 22 ± 3 N•m
(200 ± 25 in-lb).
Note: For the LH side: Connect the parking brake linkage to the parking
brake handle and install the pin to secure the parking brake linkage to the
handle.
g421530
Figure 108
4. Install the neutral safety switches. Connect the wire harness to the LH &
RH neutral safety switches.
g421553
Figure 109
5. Using a T40 torx driver , install the 4 (5/16 inch) bolts to secure the LH & RH
mounting brackets to the chassis.
6. Using a T40 torx driver , install the 4 (5/16 inch) bolts to secure the LH &
RH pod tubes to the chassis.
7. Install the LH & RH pods. Refer to Left Hand Pod Installation ( page 6– 21 )
and Right Hand Pod Installation ( page 6– 23 ) .
8. Connect the battery by installing the positive cable rst, then the negative
cable to the battery .
2000 Series Z MASTER®Service Manual Page 7–9 Drive: Service and Repairs
3460-328 Rev A

Table of Contents

Other manuals for Toro Z MASTER 2000 Series

Related product manuals