OPERATOR’S MANUAL
series  Robot Controller
5.2.5  Quitting Data Editing [SAVE] 
 (1) Function 
Saves an edited data in a file and quits editing data. 
 (2) Procedures 
(a)  Step 1:  Save data. 
Select the data display mode as shown below (i.e., the cursor is not present 
on the command line). 
 
 P O I N T   X Y     Z
↑ 
  P O I N T 0 0 0 0 3 = 1 0 0 , 1 0 0  ,      1 0 0 ,
    P O I N T 0 0 0 0 4 = 2 0 0 , 2 0 0  ,      2 0 0 ,
 P  O  I  N  T  0  0  0  0 5 = 300 , 300 ,      3 00 ,
    P O I N T 0 0 0 0 6 = 4 0 0 , 4 0 0  ,      4 0 0 ,
↓ 
  P O I N T 0 0 0 0 7 = 5 0 0 , 5 0 0  ,      5 0 0 ,
P O I N T 0 0 0 0 5  w /  . w o r  l  d
  S  A  V  E    P  R  G  F U L L T R A N S    P  Y  L  D >
 
Press [SAVE], and the system asks with a confirmation message if you wish 
to save the edited data. 
 
 P O I N T   X Y     Z
↑ 
  P O I N T 0 0 0 0 3 = 1 0 0 , 1 0 0  ,      1 0 0 ,
    P O I N T 0 0 0 0 4 = 2 0 0 , 2 0 0  ,      2 0 0 ,
 P  O  I  N  T  0  0  0  0 5 = 300 , 300 ,      3 00 ,
    P O I N T 0 0 0 0 6 = 4 0 0 , 4 0 0  ,      4 0 0 ,
↓ 
  P O I N T 0 0 0 0 7 = 5 0 0 , 5 0 0  ,      5 0 0 ,
[  S A V E  ]  O K    T H E N < E X E > w /  .  w o  r  l  d
  S  A  V  E    P  R  G  F U L L T R A N S    P  Y  L  D >
 STE 80720 
– 5-16  –