OPERATOR’S MANUAL
series Robot Controller
Enter a desired name ("LOAD000010" in this example) and press the EXE
key. The display changes as follows:
L O A D W E I G H T O F F S E T
↑
L O A D 0 0 0 0 0 3 = 1 0 0 . 0 0 0 , 1 0 0 . 0 0 0
L O A D 0 0 0 0 0 4 = 2 0 0 . 0 0 0 , 0 . 0 0 0
L O A D 0 0 0 0 0 5 = 50 . 000 , 0 . 000
L O A D 0 0 0 0 1 0 = 0 . 0 0 0 , 0 . 000
↓
L O A D 0 0 0 0 0 6 = 5 0 . 0 0 0 , 0 . 0 0 0
0 . 0 0 0
S A V E P R G P O I N T T R A N S F I N D >
(3) Cautions
• For the newly added load data, zero (0) is set for all elements.
• When you have pressed the ESC key without specifying the name, addition of
the new data is canceled and the system returns.
STE 80720