Func. Name Descriptions
Range of
Setting
Unit
Factory
Setting
Note
F1.17
SPEC Key
Setting
Same function as multi-function input
-28 ~ +28
*Note 7
─ 0
F1.18
SPEC Key
Self-Holding
Function
0: Disable
1: Enable
0, 1 ─ 0
F1.19 Stop Mode
0: Ramp to stop + DC braking
1: Coast to stop
2: Coast to stop+ DC braking
0~2 ─ 0
F1.20
Reverse
Prohibition
0: Reverse rotation allowed
1: Reversal rotation NOT allowed
0, 1 ─ 0
*Note
9
F1.21
Switching
Frequency
The setting value is higher and the
motor noise is lower.
0~6 ─
2
*Note 8
F1.22
Overload
Decrease
Switching
Frequency
0:The switching frequency will not
be adjusted by the load of current.
1:The swithching frequency will be
auto-adjusted according to the load
of current.
0,1 ─ 1
*Note
9
F1.23
Number of
Tolerance to
Drive Fault
Set the number of tolerance to drive
fault conditions when OC, faults are
occurred during the certain time
period.
0~16 1 0
*Note
9
The color as means functions can be set during the operation.
23