Digit 34 — Safety Devices
X = Standard
Digit 35 — Factory Charge
A = Refrigerant Charge (R-134a)
B = Nitrogen Charge (R-134a Field Supplied)
C = Refrigerant Charge (R-513A)
D = Nitrogen Charge (R-513A Field Supplied)
Digit 36 — Shipping Package
A = No Skid (Standard)
B = Shrink Wrap
C = Skid
D = Skid + Shrink Wrap
Digit 37 — Flow Switch
X = No Flow Switch
A = Evaporator (NEMA 1)
B = Evaporator and Condenser (NEMA 1)
C = Evaporator (NEMA 4)
D = Evaporator and Condenser (NEMA 4)
Digit 38 — Factory Test
X = No Performance Test
C = Witness Test
D = Performance Test
N = Customer Inspection
Digit 39 — Starter Type
Y = Wye-Delta Closed Transition Starter
V = Premium AFD
Digit 40, 41, 42 — Design RLA (for starter)
*** = Selection Assigned
Digit 43 — Power Line Connection Type
A = Terminal Block
D = Circuit Breaker
F = High Interrupt Circuit Breaker
Digit 44 — Max RLA (Starter)
C = 277 Max RLA (Fixed Speed)
E = 364 Max RLA (Fixed Speed)
G = 126 Max RLA (Drive and Panel)
H = 150 Max RLA (Drive and Panel)
J = 185 Max RLA (Drive and Panel)
K = 234 Max RLA (Drive and Panel)
L = 279 Max RLA (Drive and Panel)
M = 316 Max RLA (Drive and Panel)
N = 366 Max RLA (Drive and Panel)
Q = 397 Max RLA (Fixed Speed)
R = 476 Max RLA (Fixed Speed)
T = 598 Max RLA (Fixed Speed)
U = 779 Max RLA (Fixed Speed)
V = 197 Max RLA (Drive and Panel)
W = 241 Max RLA (Drive and Panel)
X = 292 Max RLA (Drive and Panel)
Y = 367 Max RLA (Drive and Panel)
Z = 446 Max RLA (Drive and Panel)
1 = 549 Max RLA (Drive and Panel)
2 = 176 Max RLA (Drive and Panel)
3 = 223 Max RLA (Drive and Panel)
4 = 280 Max RLA (Drive and Panel)
5 = 335 Max RLA (Drive and Panel)
6 = 411 Max RLA (Drive and Panel)
7 = 455 Max RLA (Drive and Panel)
Digit 45 — Under/Over Voltage Protection
X = None
U = With Under/Over Voltage Protection
Digit 46 — Operator Interface
T = Tracer AdaptiView™ TD7 Display
Digit 47 — Digital Communication Interface
X = None
8 = Modbus™ Interface
B = BACnet
®
Interface (MS/TP)
P = BACnet Interface (IP)
L = LonTalk
®
Interface
Digit 48 — External Water and Demand Limit
Setpoint
X = None
2 = 2–10 Vdc Input
4 = 4–20 mA Input
Digit 49 — External Base Loading
X = None
2 = 2–10 Vdc Input
4 = 4–20 mA Input
Digit 50 — Ice Building
X = None
A = Ice Building with Relay
B = Ice Building without Relay
Digit 51 — Programmable Relays
X = None
R = With Programmable Relays
Digit 52 — Chilled Water Reset
X = Chilled Water Reset - Return Water
T = Chilled Water Reset - Outdoor Air
Temperature
Digit 53 — Control Outputs
X = None
D = Chiller Differential Pressure and Percent RLA
P = Condenser Pressure (% HPC) and Percent
RLA
V = Condenser Regulating Valve Control and
Percent RLA
Digit 54 — Refrigerant Monitor Input
X = None
A = 100 ppm / 4-20 mA
B = 1000 ppm / 4-20 mA
C = 100 ppm / 2-10 Vdc
D = 1000 ppm / 2-10 Vdc
Digit 55 — Condenser Leaving Hot Water
Temp Control
X = None
H = Hot Water Temp Control
Digit 56, 57, 58 — AFD Output Amps
000 = Not Applicable (Wye-Delta Starter)
*** = Selection Assigned
Model Number Descriptions