12 | IM-112 DECEMBER 2019
Vertical Turbine Pumps
2001299 - VTP- IOM
12 | IM-112 DECEMBER 2019
Vertical Turbine Pumps
2001299 - VTP- IOM
12 | IM-112 DECEMBER 2019
Vertical Turbine Pumps
2001299 - VTP- IOM
Vertical Turbine Pumps
Pre-installation
Document Name: 2001299-VTP-IOM-EN Page 12 of 67
Revision 3 Copyright © 2014, Weir Floway, Inc. All Rights Reserved. Issue Date: December 12, 2014
4 Pre-installation
4.1 Receiving and Unloading
When receiving the shipment, extreme care must be taken while unloading.
Use a forklift or crane to unload the equipment.
Do not drop the unit, or any parts, as damage can cause trouble in assembly and operation of the units.
Inspect the unit for signs of transit damage before beginning to uncrate or placing in storage. If damage
is evident notify the local transporting company agent before uncrating and file a claim with the agent.
4.2 Storage
If the unit is to be stored prior to installation, carefully select a storage space where the unit will not be
subjected to excess moisture, extreme weather conditions, corrosive fumes, or other harmful conditions.
Carefully inspect the unit and clean the rust spots on the machined surfaces with a fine emery cloth.
Coat machined surfaces with a rust preventative.
Protect the pump from any dust, dirt, or debris from entering the unit. Wrap all openings with a heavy
gauge polyethylene and tape tightly to seal.
If the unit is stored for a long period of time it should be periodically inspected and cleaned as required.
Contact the factory for special long term storage (greater than 4 months) requirements for the unit
supplied.
DANGER
LIFTING DEVICE SAFETY
Use mechanical lifting devices to lift heavy or awkward components.
Lifting devices must be in good condition, certified, and tagged.
Lifting devices of adequate capacity must be used whenever they are required.
Personnel must never work under suspended loads.
DANGER
LIFTING POINT SAFETY
Check that the lifting lugs are in suitable condition for lifting, before lifting pump parts.
NOTICE
These provisions are applicable to Trillium Pumps USA pump components only. For
the appropriate storage procedures for non-Trillium items (for example, drivers, mechanical
seals, auxiliary equipment, etc.), refer to specific requirements from the manufacturer.