Vertical Turbine Pumps
Decommissioning and Disposal
Document Name: 2001299-VTP-IOM-EN Page 54 of 67
Revision 3 Copyright © 2014, Weir Floway, Inc. All Rights Reserved. Issue Date: December 12, 2014
To decommission and dispose of a pump unit, Trillium Pumps USA recommends the following steps:
1. Flush the pump of all hazardous pumpage using the necessary safety precautions.
2. Isolate the pump electrically, hydraulically, and mechanically (reference LOTO warning).
3. Drain all equipment fluids such as driver oil, thrust bearing oil, etc.
4. Disconnect the pump electrically, hydraulically, and mechanically.
5. Remove the driver, seal, and all other auxiliary equipment.
6. Remove the pump unit.
7. Disassemble the pump unit as required for disposal.
8. Follow all applicable environmental, health, and safety regulations, laws, and requirements to dispose of
the equipment and any hazardous materials.
WARNING
RESALE OF PUMPS AND PARTS
Due to the highly engineered nature of vertical turbine pumps, Trillium Pumps USA does
not recommend reselling used pumps or pump parts. Potentially unsafe conditions could
be created by using pumps and pump parts in applications for which they are not
intended for. Furthermore, used parts may be unsafe and not fit for any use due to
corrosion, wear, or other damage.
NOTICE
For drivers, mechanical seals, and other auxiliary equipment, refer to the respective
manufacturer's IOM for further details regarding decommissioning and disposal.