Safety
Requirement
The correct function of all emergency stop buttons must be checked monthly (see maintenance schedule)!
Should errors or functional deviations occur as a result of the test, the machine is deemed not to be ready for
operation and must not be put into operation until the cause has been clarified!
Non-observance can lead to injuries or damage to the machine!
If you have any questions, contact our experienced Technical Support in your local area.
General test procedure for emergency stop buttons:
The machine can be referenced before starting the test. However, this is not mandatory.
1. Set the main switch to position "1".
2. Perform test - see description below.
3. With correct function: Main switch drops to position "+".
4. Move main switch to the initial position "0".
5. Return main switch to position "1" and continue the test series or further processing.
ENGLISH (Translation) 35