Page #46 background image
43
4.2. Gap/Black Mark Sensor CalibrationSelf-testDump
mode
While calibrate the gap/black mark sensor, printer will measure the label length, print
the internal configuration (self-test) and then enter the dump mode.
Please follow the steps as below.
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber will do
during the 5 blinks).
The LED color will be changed as following order.
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green
It calibrates the sensor and measures the label length and prints internal
settings then enter the dump mode.
Note:
Please select gap or black mark sensor by Diagnostic Tool or by GAP or BLINE
command prior to calibrate the sensor.
For more information about GAP and BLINE command, please refer to TSPL2
programming manual.

Other manuals for TSC TDP-247

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TDP-247 and is the answer not in the manual?

TSC TDP-247 Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Communication InterfaceUSB 2.0, RS-232
Power Supply100-240V AC, 50/60 Hz
Operating Temperature41°F - 104°F (5°C - 40°C)
Operating Humidity85% non-condensing
Max. Print Width4.09" (104 mm)
Label Width1.18" - 4.33" (30 mm - 110 mm)
Storage Temperature-40 ~ 60°C (-40 ~ 140°F)

Related product manuals