Tuttnauer ELARA - Service Manual

Tuttnauer ELARA
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OPERATION
&
MAINTENANCE
MANUAL
Pre-vacuum Table–top Autoclave
Model ELARA
Cat. No. MAN205-0342001EN Rev D
Tuttnauer Europe b.v., Paardeweide 36, 4824 EH, Breda, P.O. Box 7191, 4800 GD Breda, Netherlands.
+31/76-5423510,
Fax: +31/76-5423540

Questions and Answers

  • D
    Donna HillJul 31, 2025
    What to do if the Tuttnauer ELARA Oven display is not activated?
    • K
      Kelsey OrtizJul 31, 2025
      If the Tuttnauer Oven display is not activated, first verify that the main switch is in the ‘On’ position. Next, make sure the power cord is properly connected to both the machine and the power source. Finally, verify that there is electrical power in the main source.
  • P
    Paige RamirezAug 14, 2025
    What to do if the Tuttnauer ELARA Oven printer does not print?
    • A
      andrewwarrenAug 14, 2025
      If the printer of your Tuttnauer Oven isn't printing, start by ensuring paper is properly inserted into the printer. If that doesn't work, try switching off the machine and then switching it back on while pressing the feed button on the printer. If the printer prints a test printout or doesn't print the test printout, contact the dealer to solve the problem.

Summary

SAFETY INSTRUCTIONS

PRODUCT INFORMATION

Water Quality Requirements

Specifies physical characteristics and contaminant limits for water used in the autoclave.

USER INTERFACE

Error and Operational Messages

Lists and explains error codes and operational messages for the autoclave, with corrective actions.

STERILIZATION PROGRAMS

Test Program: B&D Test

Bowie & Dick test program to verify air removal and steam penetration.

Test Program: VacTest

Vacuum test program to check the system's ability to maintain vacuum conditions.

PARAMETER AND DATA MANAGEMENT

INSTALLATION AND SETUP

Filling Water Reservoir

Step-by-step guide for filling the mineral-free water reservoir correctly.

STERILIZATION PREPARATION

Instrument Cleaning and Prep

Essential steps for cleaning and preparing instruments before sterilization.

Loading Packs

Proper methods for packing and loading items in trays to ensure effective sterilization.

OPERATING INSTRUCTIONS

Startup and Preheating

Instructions for turning on the autoclave and initiating the preheating stage.

Door Operation

Steps for safely opening and closing the autoclave chamber door.

Loading the Chamber

Guidance on correctly loading the autoclave chamber according to preparation instructions.

Cycle Execution

How to select and start a sterilization cycle, and monitor its progress.

Unloading and Post-Cycle Checks

Procedure for safely unloading the chamber and verifying sterilization results.

MAINTENANCE AND SERVICE

Preventive Maintenance Schedule

Outlines periodic maintenance tasks by operators and technicians, including daily, weekly, and periodic checks.

TROUBLESHOOTING GUIDE

Tuttnauer ELARA Specifications

General IconGeneral
TypeTabletop Autoclave
Voltage230V
Frequency50/60 Hz
Chamber Volume23 L
Power2200W
Sterilization Time Range4 - 30 minutes
Chamber MaterialStainless steel
Exterior MaterialStainless steel
Door TypeAutomatic
Safety FeaturesOverheat protection