Tyco Electronics Galaxy SC Controller J85501F-1
Issue 13 February 2001 Operation 6 - 23
The following example illustrates how to configure the connected
equipment ID:
CHA DS1,CID=“MCS”
This command identifies the connected equipment on data switch port 1
(DS1) as an MCS controller. For the other data switch ports substitute
DS2, DS3, or DS4 for DS1. It may also be necessary to change the
password used for the connected equipment. To do this, use the
following command substituting your password for “password”:
CHA DS1,PWD=“password”
To enter pass-thru mode set the data switch port using the following
command:
OPE DS1,STT=“PASS-THRU”
Alarm Reporting
Mode
Like pass-thru mode, for most applications, only the connected
equipment ID needs to be configured for reporting mode. To enter
reporting mode use the following command:
STA DS1,REN=1
If call out is required it will also be necessary to configure the connected
equipment alarm. The following examples illustrate how this can be
done for the connected equipment on data switch port 1:
CHA P2,PHN=“123-4567” configure call-out phone number 2
CHA CEA1,DES=“MCS Alarms”
configure the alarmdescription
CHA CEA1,DST=“P2” configure alarm call-out destination
to be P2
CHA CEA1,NOO=1 configure the alarm to notify on occur
The call-out destination phone number may require additional
configuration, see the section on call-out. For the other data switch ports
substitute CEA2, CEA3, or CEA4 for CEA1. To see if any data switch
connected equipment alarms are active use the following command:
ALA DSW