SECTION 6. TESTS AND ADJUSTMENT
1.HYDROSTATIC PEDAL AND
NEUTRAL ADJUSTMENT
Reason:
To ensure that tractor does not move unless forward
or reverse pedal is depressed.
Procedure:
1.Operate the hydrostatic control pedals.They should
return by themselves to the neutral position.If
pedals do not operate properly,check pedals and
linkage for damage or wear.
2.Start engine and run at low idle.
3.Place range shift lever in LOW gear. Tractor
should not move.If tractor moves,note direction,
and adjust neutral return lever as follows:
6. loosen the locking nut that holds the rod and
the elbow to the transmission.
7.Using a wrench,Turn the rod to move
the rod down to eliminate reverse,or up to
eliminate forward movement .
8.Tighten the elbow and the nut .
4.Shut engine OFF,engage park brake.
5. On the right side of the tractor,below the forward
and reverse control pedals,locate the rod .The rod
must be turned to perform the neutral adjustment
8.Tighten the elbow and the nut .
9.start engine and run at low idle.
10.Place range shift lever in LOW gear.Tractor
should not move.If tractor moves,repeat steps
4 through 11 until movement is eliminated.
4-13