5. Place the BOARD on the VM20 BEAMS.
Screw type: D6x50 mm with countersinking head.
Completed PANEL.
6. The slings that go to the E V-100 LIFTING BRACKETS should form a maximum angle of 60º between them.
I.e., the sling or chain that goes to each LIFTING BRACKET E V-100 will have at least the same length of the
separation between the two brackets.
The angle between the raising chains will be of maximum 60º.
Max. 60º
M
a
x
.
3
0
º
M
a
x
.
3
0
º
Max. 60º