FAULT
CODE
COMPONENTS CONCERNED POSSIBLE CAUSES CONSEQUENCES
CONDITIONS FOR EXIT
OF THE SECURITY
83 ? Fuse no 1 Broken ABSENCE OF SUPPLY 230 V ~ ? ?
84 ? Fuse no 2 Broken ABSENCE OF SUPPLY 24 V ? ?
85 ? Fuse no 3 Broken ABSENCE OF SUPPLY 12 V ? ?
90 ? Fuse broken ? ? ?
91 DO1 Doser, GROUP 1
First fill fault: the pulse start remained nil for
more than 3 sec, or did not fall below 30
pulses per second in less than 3 minutes.
Coffee boiler filling cycle
stop: MPO stop - Closure
of EV1 and EP1
Fault eliminated and
machine reset performed
92 DO2 Doser, GROUP 2
First fill fault: the pulse start remained nil for
more than 3 sec, or did not fall below 30
pulses per second in less than 3 minutes.
Coffee boiler filling cycle
stop:
MPO stop - Closure of
EV1 and EP1
Fault eliminated and
machine reset performed
93 DO3 Doser, GROUP 3
First fill fault: the pulse start remained nil for
more than 3 sec, or did not fall below 30
pulses per second in less than 3 minutes.
Coffee boiler filling cycle
stop:
MPO stop - Closure of
EV1 and EP1
Fault eliminated and
machine reset performed
94 DO4 Doser, GROUP 4
First fill fault: the pulse start remained nil for
more than 3 sec, or did not fall below 30
pulses per second in less than 3 minutes.
Coffee boiler filling cycle
stop:
MPO stop - Closure of
EV1 and EP1
Fault eliminated and
machine reset performed
99
Failure group 4
101
Incompatibility of version
255
BGX update failure