Continuous/stop cycle key
Existing functions:
1. Stop an infusion in progress
2. Start a continuous cycle (without dosing) manually
3. Extend a dose manually at the end of a cycle.
4. To have a 3
re
programmable cup volume (volumetric), when the cycle is started with the continuous
key.
- I.e 3 new doses in the case of a Dosamat (with filter holder detection).
a. 1 small cup - 2 small cups - 3 small cups (existing)
b. 1 large cup - 2 large cups - 3 large cups (existing)
c. continuous dose (PF1T) – continuous doses (PF2T) – continuous doses (PF3T)
-Only one extra dose when there is no Dosamat (refer to CIM)
5. Barista rinsing before the cycle.
Some of these functions are mutually incompatible; the customer should be able to choose the function he
wants to use.
The choice of functions on the "continuous" key is common to all groups. If a function is selected, it is
applied to all the groups on the machine.
Each time you press the line the value is incremented
as follows: OFF ; 1sec ; 2sec ; 3sec ; 4sec ; 5sec ; 6
sec ; OFF ; 1sec ; 2sec ; etc...
OFF= function de-activated
Xsec = the Barista rinsing cycle will have a duration of
Xsec
To activate Continuous/Stop dosage