Self time adjustment (levels 1, 2 and 3)
Only for DOSAMAT machines.
Activating the timer delay makes it possible to place the cups in the SELF mode before the automatic cycle
starts.
Steam adjustment (level 1, 2 and 3)
To adjust the steam boiler pressure.
Use the + and – keys to adjust the desired value.
Adjustment range: 0 to 10 sec, default setting, 1 cup: 1.5
seconds
Confirm the adjustment to save the settings.
Switch to 2-cup adjustment
Use the + and – keys to adjust the desired value.
Adjustment range: 0 to 10 sec, default setting, 2 cups: 2.5
seconds
Confirm the adjustment to save the settings.
Switch to 3-cup adjustment
Use the + and – keys to adjust the desired value.
Adjustment range: 0 to 10 sec, default setting, 3 cups: 3
seconds
Remember to confirm the adjustment to save the
settings.
pressure.
Use the + and – keys to adjust the desired value.
Adjustment range: 0.7Bar to 1.4Bar, default setting 1Bar
Confirm the adjustment to save the settings.