NAME DESCRIPTION VALUE
Heating time (in minutes) Here the time for rising the boiler temperature from
the specied inthe Maximum coffee tempera-
turesettingisspecied.Beforethistimepassthe
boiler temperature will gradually increase from
minimum Minimum coffee temperature setting
to maximum Maximumcoffeetemperature set-
ting in proportion to the time passed. If 0 is speci-
ed,thentheboilertemperatureisalwaysheldon
thelevel,speciedintheMinimum coffee tem-
perature setting. Timekeeping (during which the
temperature starts rising) will start after making a
coffee-baseddrink.The timeis specied by the
Heating delay setting.
Enter number
Minimum solubles temperature
Here the minimum permissible temperature for
making the instant drinks (or hot water) is set.
The vending machine starts making coffee if the
actual temperature differs downward from the
temperature, specied here by no more than 3
degrees. Otherwise, before making coffee, the
vending machine waits for the boiler to heat up.
The upward difference is not limited. It should be
noted that between making drinks the tempera-
ture in the boiler is maintained in accordance with
the Minimum coffee temperature setting.
This setting comes into effect only at the moment
of instant drink making. Temperature, specied
here, shouldn’t be higher than the temperature,
specied in the Minimum coffee temperature
setting.
Enter temperature
Steam boiler temperature
Steam boiler temperature setting for the vending
machine with fresh milk option (FRESH MILK)
Enter temperature
Show temperatures
• Included - Boiler heating temperature dis-
play on the vending machine screen when in
vending mode is ACTIVATED.
Included
Disabled
Buttons(seeg.9.17pos.1):
1. Cool Boiler - Automatic boiler cools due to pumping cold water through it to a temperature of 45 degrees.
2. Empty Boiler - The machine empties the boiler, after the devastation of the boiler must be switched off, un-
screw the bottom hose and turn on the machine (following the inclusion of machine translated it into service mode,
where it will open the valve by pouring water through the rest of the bottom of the boiler).
3. Fill Boiler-Themachinellstheboiler.Iftheboilerdoesnothavetimetobelledduringpumpoperation-30sec.,
The cycle repeats until discharge water into the canister waste