EasyManua.ls Logo

Vaisala RVP900 - Page 286

Vaisala RVP900
512 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USER’S MANUAL__________________________________________________________________
284 _________________________________________________________________ M211322EN-D
RHV Selects dual polarization correlation coefficient ρ
HV
data.
8-Bit ρ
HV
Format—The correlation coefficient is
computed on the interval 0.0 to 1.0 using a square root
weighting of the unsigned byte N as:
0 : Indicates no ρ
HV
data available at this range
1 : 0.0000 (dimensionless)
2 : 0.0629
253 : 0.9980
254 : 1.0000
255 : Reserved Code
16-Bit ρ
HV
Format—The correlation coefficient is
computed on the interval 0.0 to 1.0 linearly from the
unsigned word N as:
0 : Indicates no ρ
HV
data available at this range
1 : 0.0 (dimensionless)
65534 : 1.0
65535 : Reserved Code
SQI Selects Signal Quality Index data. This dimensionless
parameter uses the same 8-bit and 16-bit data formats as
RHV ( ρ
HV
).
LDR Selects Linear Depolarization Ratio, measured either on
the horizontal receive channel while transmitting
vertically, or on the vertical receive channel while
transmitting horizontally.
8-Bit LDR Format—The level in decibels is computed
from the unsigned byte N as:
dB = 45.0 + (N1) / 5
This spans an asymmetric interval around zero decibels,
and allows for cross channel isolation as large as 45 dB.
The overall range is from -45.0 dB to +5.6 dB in 0.2 dB
steps as follows:
0 : Indicates no LDR data available at this range
1 : -45.0 dB
226 : 0.0 dB
254 : +5.6 dB
255 : Reserved Code
16-Bit LDR Format—Same as 16-bit deciBel format.
RHO Selects Signal Quality Index data. This dimensionless
parameter uses the same 8-bit and 16-bit data formats as
RHV ( ρ
HV
).
PHI Selects the cross channel differential phase. This parameter
uses the same 8-bit and 16-bit angular data formats as PDP
(φ
DP
).

Table of Contents