Appendix E _____________________________________________________ Time Series Recording
VAISALA______________________________________________________________________ 437
E.6.2 Case 1: TS Recording on a Local
RVP900
0916-212
Figure 70 TS Record on Local RVP900
In this case, the TS Switch is set to place the real-time IQ values from the
IQ-Data Process into the TS API. These are extracted and recorded to local
disk by the TS Archive process. The RVP900 may still do its normal data
processing tasks, as shown in Section E.6.1 RVP900 in Normal Real-Time
Operation on page 430, while TS data are being recorded.
Utility Settings
This configuration records to a local disk on the RVP900. Typically only
a 20 GB disk is provided with a standard RVP900 so recording capability
is limited unless a large custom disk is added. In either case, the recording
should be done to a dedicated data partition, NOT the “/” partition. The
reason for this is that if the “/” partition fills-up, the system will crash.
However, if the separate data partition fills-up, then the system will stop
recording, but otherwise function normally.
TS Switch: Local RVP900
TS Archive: Record