10. Verify the V command shows Tx/Clk:Okay, indicating the RVP901
DAC is locking properly.
11. Reduce the SigGen output to -20 dBm and verify the locking is still
okay.
12. Vary the frequency by 10 KHz (0.01 MHz) and check that the lock is
lost.
13. Return to the center frequency and verify that lock returns.
Test Passed
For Customer_________________________________ Date__________
For Vaisala___________________________________ Date__________