Engineer programming via the browser
Installation & Configuration Manual
Swedish Region:
– SSF1014:3 Larmclass 1
– SSF1014:3 Larmclass 2
– Unrestricted
Belgium Region:
– TO-14 (EN50131 Grade 2 based)
– TO-14 (EN50131 Grade 3 based)
– Unrestricted
Switzerland Region:
– SES EN-CH-Grad 2
– SES EN-CH-Grad 3
– Unrestricted
Spanish Region
– EN50131 Grade 2
– EN50131 Grade 3
German Region
– VdS Class A
– VdS Class C
– Unrestricted
France
– NF&A2P - Grade 2
– NF&A2P - Grade 3
– Unrestricted
Unrestricted Grade
A Security Grade setting of Unrestricted does not apply to any regionally approved
security restrictions of the installation. Instead, the Unrestricted setting enables an
engineer to customize the installation by changing security policy options and
configuring additional options which do not comply with the selected regional
security compliance.
Unrestricted configuration options are denoted in this document by the following
symbol:
See System Options for details of configuring system policies.
17.9.4.5 Clock
This window allows you to program the date and time on the panel. The controller
contains a Real-Time Clock (RTC) that is battery backed to preserve the time and
date information in the event of power failure.
1. Select Configuration > System > Clock.
The following window will be displayed.