Installation & Configuration Manual
Anti-Masking PIR
The following diagram shows the Anti-Masking PIR configuration:
7.1.3.2 Wiring the Outputs
The expander and PSU relay logical outputs can be assigned to any of the SPC
system outputs. The relay outputs can switch a rated voltage of 30V DC at 1A
(non-inductive load).
When the relay is activated, the Common terminal connection (COM) is switched
from the Normally Closed (NC) to the Normally open (NO) terminal.
The following diagram shows the wiring of an active, high output: