7. Crank the engine for 15 seconds and observe the
multimeter display.Record results.
The observed voltage reading should match the
observed readingfrom the battery load test. If the voltage
drop is HIGHER than observed on the battery load
test, check cables, wiring and connectors between the
solenoid and the battery.
8. Select AMPS on the multimeter, or if equipped, install the
multimeter inductive clampon the POSSITIVE (+) battery
cable.
9. Crank the engine for 15 seconds and observe the
multimeter display. Record results.
The observed current draw (amps) should not exceed
190 amps. See SPECIFICATIONS -Engine Parameter
Specifications. If the current draw is HIGHER than
specified, replace thestarter motor. See SECTION 4 -
REMOVE EXTERNAL ASSEMBLIES - Starter Motor.
45