Outgoing Call Access 144
SBX IP 320 Features & Operation Guide
The SBX IP 320 system administrator wants to use this cheaper carrier for all long distance calls
(e.g., dial 0314502628, 082314504628).
Ex. 2 Select CO group - The SBX IP 320 system is connected with two carriers (one carrier is
carrier A, the other carrier is carrier B). Carrier B is used for international calls, and Carrier A
is used for all other calls. The international call access code is 001.
The SBX IP 320 system administrator wants to program Carrier B to be used for only
international calls.
PGM 220 PGM 221 (LDT) PGM 222 (DMT)
LCR MODE
MO1, M02, M11, M12
(Loop LCR enabled)
Bin 000
LCR TYPE: COL
LCR CODE: 0
DMT: 00 00 00
Bin 00
Remove Position: 01
Remove Number: 01
Add Position: 01
Add Digit: 082
PGM 141 PGM 117 PGM 161-3
Set CO Lines from carrier "A"
to CO group 1.
Set CO Lines from carrier "B"
to CO group 2.
Enable access CO group 01,
02
Override 1st CO Group: OFF