Attendant Service 10
SBX IP 320 Features & Operation Guide
Disable Outgoing Access
The Attendant can take a particular CO line out of service. CO calls will not be able to be made
through the CO line; incoming CO calls are not affected.
Operation
To set a CO line in/out-of-outgoing service from the Attendant:
1. Press the [TRANS/PGM] button.
2. Dial 073.
3. Press the desired {CO line} FLEX button; a confirmation tone will sound when the status
(in or out-of-outgoing-service) of the selected CO line is changed.
4. Press the [SPEAKER] button to return to idle.
Conditions
Any Attendant can use this feature.
The LED of the {CO line} FLEX button which is out-of-outgoing-service is flashing in
Attendant station but is fully lit in other stations.
To release the-out-of-outgoing-service, press the flashing {CO line} FLEX button at the
Attendant station.
Though the desired CO line is busy, the Attendant can still make the CO line
out-of-outgoing-service. The out-of-outgoing-service feature will take effect after the CO
line goes to idle.
DSS/BLF Consoles
Attendants and other DKTUs may be equipped with DSS/BLF consoles which provide
additional buttons for more convenient operation. The consoles are arranged as flexible mapped
units. The DSS/BLF consoles are initially assigned with programming as one of 3 maps. All
buttons of any map are programmable.
The DSS/BLF consoles each require a separate line connection to the KSU, and take up a station
number.
Conditions
There is no limit to the number of DSS/BLF consoles in a system.

Table of Contents