Conditions
While entering the account code, the current call is put on mute mode.
The user may enter the account code before a call conversation is established.
Admin Programming
Refer to the SBX IP 320 Installation Manual, SMDR Account Enter Code
(PGM 106 - Flex 7)
Authorization Code
If the Station is programmed to enter the authorization code by ADMIN programming, the
authorization code must be entered to access a CO line. An authorization code can be used for
SMDR, DISA account code.
Note: Personal authorization codes should be kept secure by the System Attendant and
individual Station Users to avoid fraudulent phone calls being made.
An authorization code is assigned as 3-11 digits as applicable; each station has a different
authorization code.
Operation
To access a CO line using an authorization code:
1. When attempting CO line access, a DND warning tone will be heard. Enter the
authorization code.
2. Press the # key (if 5 digits authorization code type is set according to PGM161-FLEX21,
the # key is not needed). If valid, the CO line will be connected; if not valid, an error tone
will be presented.
To register the authorization code on a Station:
1. Press the [TRANS/PGM] button.
2. Type 31.
3. Enter the authorization code, and press the # key (if 5 digits authorization code type is set
according to PGM161-FLEX21, the # key is not needed).
4. Press the [HOLD/SAVE] button to accept changes.