Order no. 313-6CF13
Number of flags 8192 Byte
Number of data blocks 4095
Max. data blocks size 64 KB
Max. local data size per execution level 510 Byte
Blocks
Number of OBs 15
Number of FBs 2048
Number of FCs 2048
Maximum nesting depth per priority class 8
Maximum nesting depth additional within an
error OB
4
Time
Real-time clock buffered
ü
Clock buffered period (min.) 6 w
Accuracy (max. deviation per day) 10 s
Number of operating hours counter 8
Clock synchronization
ü
Synchronization via MPI Master/Slave
Synchronization via Ethernet (NTP) no
Address areas (I/O)
Input I/O address area 1024 Byte
Output I/O address area 1024 Byte
Input process image maximal 128 Byte
Output process image maximal 128 Byte
Digital inputs 8064
Digital outputs 8064
Digital inputs central 1008
Digital outputs central 1008
Integrated digital inputs 16
Integrated digital outputs 16
Analog inputs 503
Analog outputs 503
Analog inputs, central 248
Analog outputs, central 248
Integrated analog inputs 0
Integrated analog outputs 0
VIPA System 300SHardware description
Technical data
HB140 | CPU-SC | 313-6CF13 | GB | 15-50 42