EasyManua.ls Logo

Wacker Neuson RC50

Wacker Neuson RC50
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
Control stand
132
BA RC50_RC70 en 00
4.02.02 Replacing the circulating air filter of the air-conditioning system
1 2 3 1
NOTE
Change the filters according to the amount of dust
accumulated.
Switch off diesel engine and remove ignition key.
Loosen screws [1] and remove with the cover [2] and remove the filter
element [3].
Replace the filter element [3] by a new one.
Mount the cover [2] with the filter element [3] and tighten screws [1].
4.02.03 Replacing the fresh air filter for the driver's cab
3 1 2 1 2 4 1
NOTE
Change the filters according to the amount of dust
accumulated.
NOTE
Check the proper alignment of the filter element (airflow ↑).
Switch off the diesel engine and remove the ignition key.
Undo the screws [1].

Table of Contents