Maintenance
Drive unit/diesel engine
140
BA RC50_RC70 en 00
Check the operating readiness of the air filter while the diesel engine is
running:
Start diesel engine and shortly rev up to maximum speed.
a
The air filter pilot light is not flashing on the information display: Air
filter cartridge [1] and the safety cartridge [2] are ready for operation.
a
Air filter pilot light flashing on the information display: Replace the air
filter cartridge [1] and/or the safety cartridge [2].
4.03.09 Replacing air filter cartridge
312
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 °C (86 °F).
Fold up the clips [1].
Remove dust collection container [2].
Clean the inside of the dust collectors.
Pull out the air filter cartridge [3].
Insert a new air filter cartridge.
Put on the dust receiver bin [2].
Snap shut the clips [1].
Check the operating readiness of the air filter.
4.03.10 Replacing the safety cartridge at the air filter
Replace the safety cartridge:
after having changed the air filter cartridge five times.
After 2000 operating hours at the latest.
If the air filter pilot light is flashing on the information display after
having replaced the air filter cartridge.
If the air filter cartridge is defective.

Table of Contents