Maintenance
Hydraulic oil supply
146
BA RC50_RC70 en 00
1
2
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 °C (86 °F).
Unscrew the barrel casing [1].
Unscrew the filter insert [2] from the filter head and replace with a
new one.
Clean the inside the barrel casing [1].
Screw in and tighten the barrel casing [1] in the filter head again.
Check hydraulic system for leaks.
4.04.04 Replacing the filter insert of the pressure filter for the steering system
$ Only lubricants with this symbol are permitted ("Technical data",
page 160 onwards).
1
2
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 °C (86 °F).
Unscrew the barrel casing [1].
Unscrew the filter insert [2] from the filter head and replace with a
new one.
Clean the inside the barrel casing [1].