11
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2329371
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION IN ACCORDANCE WITH ATEX
3.2 PERMISSIBLE DEVICE COMBINATIONS
The following powder spray guns may be connected to the EPG-SPRINT X:
Manual spray guns
Corona spray gun PEM-X1, PEM-X1 CG, PEM-C3, PEM-C4,
PEM-C4-Ergo
Tribo spray gun PEM-T3
Automatic spray guns
Corona spray gun PEA-C3, PEA-C4
Corona spray gun PEA-C3XL, PEA-C4XL
Tribo spray gun PEA-T3
Tribo spray gun PEA-T3XL
Older or other gun types may only be connected to the control unit after rst checking
their suitability with Wagner.
For permissible device combinations for the USA and Canada, see Chapter 14.5 "FM Approval".
The device is suited for use in potentially explosive areas, in accordance with Test Certi cate
PTB 12 ATEX 5001.
0102
II 3(2)D IP 64 80 °C
CE: European Communities
0102: Number of noti ed body which issues the recognition of quality assurance in
production.
Ex: Symbol for explosion protection
II: Device class II
3: Category 3 (Zone 22)
(2): Impact on equipment of category 2
D: Ex-atmosphere dust
IP64: Protection class 64
80 °C: Temperature class: maximum surface temperature < 80 °C; 176 °F