A3 TABLE OF PARAMETERS
Parameter Value Description
C11 Gun charging type
cor
(Factory setting)
Wagner Corona spray guns can be
connected to the unit; a Tribo gun will
trigger a fault.
tri Wagner Tribo guns can be connected to the
unit; a Corona gun will not trigger a fault.
aut Tribo or Corona spray guns can be
connected to the unit. The system only
changes to the correct type after it is rst
switched on with the spray gun's trigger or
the connected CCM module.
C12 Selection reset function
OFF The selection function is switched o . A
selection is retained until another selection
is made.
ON
(Factory setting)
Selection function is switched on: after
5 seconds, the selection automatically
returns to the powder quantity setting.
C13 Lock
OFF
(Factory setting)
Lock is deactivated.
ON Lock is activated, values cannot be
changed, user can only select recipes and
control functions.
Recipe values cannot be changed.
Pro Operating inhibit sometimes activated.
Recipe storage is blocked, otherwise
function as in the "OFF" position. Values
can be changed temporarily.
C14 "Double Click" function
OFF "Double Click" function is deactivated.
ON
(Factory setting)
The "Double Click" function is activated -
when the manual gun's trigger is pressed
twice to switch on, the program jumps to
the "Double Click" recipe; at the next switch-
on the previous recipe is selected again.
C15 Operating hours counter
only display The actual coating hours are counted.
The numerical value displayed should be
multiplied by 100.
Examples:
0.15
0.15 * 100 h = 15 operating hours
050 50 * 100 h = 5,000 operating hours