Recipes 1-4 can be selected and saved directly using recipe buttons 5-8. Once the
recipe required has been called up, the individual coating parameters can be called up
and changed using the corresponding selection buttons. Descriptions of the individual
parameters are provided in chapters 7.7.1-7.7.8. When a parameter is changed, the LED on
the left of the recipe button  ashes to indicate that a parameter value has been changed.
The process for saving parameters is described below.
To reuse the originally set values, press the corresponding recipe button brie y.
The modi ed values are not taken over.
To save the modi ed values, press the appropriate recipe button and hold for approx.
2 seconds until the LED beside the button  ashes quickly. The modi ed values are then
saved.
7.6 CHANGING AND SAVING RECIPES
7.6.1 RECIPE NO. 14