OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2329371
6.6.1 GROUNDING THE POWDER COATING SYSTEM
1 Only use mains cables with grounding strand!
2 Connect grounding cable with booth and signal ground!
3 Connect grounding cable to an uncoated metal part of the booth!
4 Remove all paint from hooks and other hanger parts!
5 Do not wear non-conducting gloves!
6 Wear electrostatically conductive footwear!
7 The oor must be electrostatically conductive!
The footwear worn by the operators must comply with the requirements of
ENISO 20344. The measured insulation resistance must not exceed 100 MΩ (megohms).
The protective clothing, including gloves, must comply with the requirements of
ENISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megohms).
Sparks between conveyor, conveyor hooks (hangers) and work piece can occur
if electric contact points between conveyor, conveyor hooks (hangers) and work
piece are not su ciently cleaned and therefore the work pieces are not su ciently
grounded!
These sparks can cause heavy radio frequency interference (EMC).