10 DISASSEMBLY AND DISPOSAL
10.1 DISASSEMBLY
Procedure:
1. Switching o the system.
2. Lock the compressed air supply and decompress system.
3. Release electrical cable on control unit.
4. Detach hose for compressed air supply on control unit.
5. Detach hoses for the feed air, dosing air and atomizing air on the control unit.
6. Remove grounding cable on control unit.
7. Loosen retaining nuts and dismount control unit.
WARNING
Incorrect disassembly!
Risk of injury and damage to the device.
Before starting disassembly:
- Switch o the energy/compressed air supply.
- Ensure that all system components are grounded.
- Secure system against being switched back on without
authorization.
Observe the operating manuals for any work.