73
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2329371
Warning No. Warning Cause Remedy
E01 Atomizing air too low Set point cannot be reached
Causes:
Hose kinked / blocked Check hoses and hose laying
Input air pressure too low Ensure that input pressure is
greater than 6 bar
System cannot reach target
setting
Check gun and nozzle
system
E02 Dosing air too low Set point cannot be reached
Causes:
Hose kinked / blocked Check hoses and hose laying
Input air pressure too low Ensure that input pressure is
greater than 6 bar
Injector is not connected Connect injector correctly
System cannot reach target
setting
Check hoses and hose laying
E03 Feed air too low Set point cannot be reached
Causes:
Hose kinked / blocked Check hoses and hose laying
Input air pressure too low Ensure that input pressure is
greater than 6 bar
Injector is not connected Connect injector correctly
System cannot reach target
setting
Select smaller set point
value
Example: Feed air for ED
pump max. 3.5 Nm³/h
E04 Fallen below Tribo
current limit for 10 s
The Tribo current set in the
con guration cannot be reached
Causes:
Tribo air set too low Increase Tribo air
Powder not owing due to
incorrect settings for feed air
and total air
Correct feed air and total air
settings
No powder in tank Fill powder tank
The powder does not have
the required charging
characteristics
Use suitable powder