EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2329371
Parameter Value Description
C20
Reset unit to delivery
condition
NO
(Factory setting)
No action.
res All settings except recipes are reset to the
delivery condition if "res" is saved with
button 25.
C21
Vibrator motor control
after-run
10 s
(Factory setting)
Vibrator motor overruns for 10 seconds.
OFF Vibrator motor is not controlled; always o .
ON Vibrator motor is always switched on.
1 s - 240 s Vibrator motor is switched on with the
manual gun's trigger lever and overruns
for X seconds; can be set from 1 second to
240seconds.
C22
Hose purging
(dosing air without feed air)
OFF
(Factory setting)
Hose purging switched o .
1 s - 10 s Hose purging time overrun in seconds.
C23
Hose purging intensity of
dosing air
100%
(Factory setting)
Hose purging intensity 100%.
1% - 100% Hose purging intensity from 1% to 100%.
C25
Tribo current minimum
monitoring
OFF
(Factory setting)
Tribo current is not monitored.
0.1 µA - 5 µA If the Tribo current does not reach the set
values for more than 10 seconds, a warning
is issued (see Warnings and Fault Messages).

Table of Contents

Other manuals for WAGNER EPG-Sprint X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-Sprint X and is the answer not in the manual?

WAGNER EPG-Sprint X Specifications

General IconGeneral
BrandWAGNER
ModelEPG-Sprint X
CategoryControl Unit
LanguageEnglish

Related product manuals