50
PEM-X1
OPERATING MANUAL
VERSION 09/2012 ORDER NUMBER DOC 2326020
Section Type of inspection Requirements Inspection
by
Type of inspection Inspection
interval
4 Measures to take if conductive
components are insu ciently
grounded
If su cient grounding of conductive
parts cannot be ensured, their
discharge energy must not exceed
the permissible value.
BP ME/SÜ
Measurement of discharge energy.
Weekly
5 Resistance to ground of work
piece's locating point
The resistance to ground of every
work piece's locating point must not
exceed 1 megaohm (measurement
voltage must be 1000 V). The design
of the work piece receiver must
ensure that the adapters remain
grounded during coating.
BP ME/SÜ
Measure resistance to ground
(work piece receiver - ground
potential) max. 1 MOhm @ 1000 V.
Weekly
Key:
HE = Manufacturer
AG = Employer
BP = Capable person
BSB = Fire safety engineer
EFK = Electrician
UP = Trained person
FU = Function inspection
ME = Measurement
OP = Standard inspection
SI = Visual inspection
SÜ = Continuous inspection
TP = Technical inspection