8.2.3 Turn time
The automatic turning control activates a brief (0.1 - 9.9 s) UP command (=
turn time) after the sun shading products have reached the lower limit posi-
tion. Whether or not the turning is actually executed depends on what caused
the DOWN command. See Chapter 8.2.4.
NOTE If the set DOWN
run time is longer than the actual product run time, the sun
shading products remain in the lower limit position until the turning takes
place.
When using the External venetian blind or Pleated blind product set-
ting, the turn setting can be used to set a slat angle of your choice. The turn
time can also be used to open roller shutters being used as a sun shading
system by a crack after they are lowered.
8.2.4 Turn mode
Whether or not the turning is actually executed depends what caused the
DOWN command. The causes that can be programmed are manual, sun and
time switch control.
These causes can also be combined:
M
Manual
S Sun
T Time search control
M/S Manual/sun
M/T Manual/time switch control
S/T Sun/time switch control
M/S/T Manual/sun/time switch control
OFF OFF
General parameters
Run time and turn time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAREMA Quatronic dialog and is the answer not in the manual?

WAREMA Quatronic dialog Specifications

General IconGeneral
BrandWAREMA
ModelQuatronic dialog
CategoryControl Systems
LanguageEnglish

Related product manuals