115
Programme unit
1 2 3
4 5 6
7 8 9
0
1 2 3
4 5 6
7 8 9
0
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Default motor on-time / off-time
Here you determine the machine default times for
motorrotation,both”on-time”and”off-time”.
Under certain circumstances during a wash pro-
gram, e.g when the machine starts up again after
a halt in extraction due to imbalance, the machine
cannotndthe”on-time”and”off-time”valuesfor
its motor action in the current wash program. That is
when it needs to be able to find and use the default
”on-time”and”off-time”valuesstoredhere.
The values shown are those recommended by the
supplier.
Drum action,
right-hand
rotation
Drumaction,left-
hand rotation
Off-time
On-time
Time
Middle temperature cool-down
Here you determine the middle temperature for
cool-down.
When creating a new wash program you can, to
preventcreasingoftheload,usetheCOOL-DOWN
moduletoachievecontrolledcool-downofthewa-
terinthedrum.Thecool-downsequenceisdivided
into two stages:
1 wash temperature to middle temperature
Throughout this stage the machine will monitor
thecool-downrate,toensureitdoesnotexceed
thecool-downrateset(4°Cperminutewhen
the machine leaves the factory). If the rate set is
exceeded, no water will be added until the mean
value is acceptable again.
2 middle temperature to final temperature
Therateofcool-downisnotmonitoredduring
this stage. The valve opens and shuts as you
have programmed it to do.
Temp.
Time
Middle temperature
Final temperature
Temperature monitoring
LEVELQUICKCOOL-DOWN 175
LEVEL UNBALANCE 0
LEVEL LOW 135
LEVEL MEDIUM 150
LEVEL HIGH 175
MIDDLE TEMPERATURE COOL-DOWN 70 °
DEFAULT MOTOR ON TIME 0:12
DEFAULT MOTOR OFF TIME 0:03
FLUSH DELAY TIME 0:06
FLUSH ON TIME 0:10
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y
LEVEL UNBALANCE 0
LEVEL LOW 135
LEVEL MEDIUM 150
LEVEL HIGH 175
MIDDLETEMPERATURECOOL-DOWN70°C
DEFAULT MOTOR ON TIME 0:12
DEFAULT MOTOR OFF TIME 0:03
FLUSH DELAY TIME 0:06
FLUSH ON TIME 0:10
BUZZER ON BUTTON Y
MAX FILLING TIME 10:00
MAX HEATING TIME 10:00
SHOW WEIGHT TIMEOUT 0:20
PC5 BLOCKING OF HEATING N
PC5 BLOCKING OF SPINNING Y
HEAT 2 AS STANDARD Y
SERVICE ALARM HOURS Y