53
Troubleshooting
MIS COMMUNICATION
Communication between the programme unit
card A1 and the network has been interrupted.
If the power is on, be very careful when
working on the the machine.
Try to restart the machine (i.e. reset the error
code) by pressing START.
If the error returns, troubleshoot as follows:
Verify that the cable between the network and
X7 on programme unit card A1 is connected.
If the cable is properly connected, contact the
person responsible for the network.
Note!
This error code will disappear by itself after se-
veral programme starts. In case communication
has been interrupted intentionally, the machine
can be operated with no further intervention
required.